Difference between revisions of "Control application"
From aquarium-doc
Jump to navigationJump to search
| Line 17: | Line 17: | ||
* File-based communication to web application | * File-based communication to web application | ||
* Recording of WebCam picture | * Recording of WebCam picture | ||
The control application makes extensive use of the [https://abyz.me.uk/rpi/pigpio/ pigpio library]. | |||
Revision as of 14:17, 27 March 2022
The main control application of Aquarium control implements the following features:
- Data acquisition of water temperature, pH and conductivity
- Data acquisition of ambient temperature and humidity
- Fresh water refill control
- Feed control
- Water temperature control using air ventilation
- Calculation of refill tank content based on water level measurement
- Actuation of pump for water exchange
Additionally, the main control application implements the following supporting features:
- HW-Tests
- Text-To-Speech interface
- Logging
- Command interface to receive instructions from outside of the application
- Storage of recorded data in SQL database
- File-based communication to web application
- Recording of WebCam picture
The control application makes extensive use of the pigpio library.