The main control application of Aquarium control implements the following features:
- Data acquisition of water temperature, pH and conductivity
- Data acquisition of ambient temperature and humidity
- Fresh water refill control
- Feed control
- Water temperature control using air ventilation
- Calculation of refill tank content based on water level measurement
- Actuation of pump for water exchange
Additionally, the main control application implements the following supporting features:
- HW-Tests
- Text-To-Speech interface
- Logging
- Command interface to receive instructions from outside of the application
- Storage of recorded data in SQL database
- File-based communication to web application
The control application makes extensive use of the pigpio library.
The architecture of the application uses various threads.